Quick Answer: The UWELD 1C008-0080 CGA 510 acetylene regulator is a medium-duty, single-stage pressure regulator designed for compatible oxy-acetylene welding, cutting, brazing, and heating systems. It features high-contrast pressure gauges, a protected gauge arrangement, and an impact-absorbing adjustment knob. The published product illustration identifies a CGA510 cylinder inlet and 9/16"-18 left-hand outlet. Industrial buyers should verify pressure ratings, gas compatibility, connection specifications, and product-specific quality documents before bulk purchasing.
For welding equipment distributors, industrial importers, and professional gas equipment buyers, choosing the correct acetylene regulator involves more than matching a cylinder connection.
A regulator must control acetylene delivery within the permitted operating conditions while remaining compatible with the connected cylinder, hose, protective devices, and torch system.
An unsuitable regulator can create installation problems, pressure-control concerns, customer returns, and serious safety risks.
The UWELD 1C008-0080 ACE is positioned as a medium-duty acetylene pressure regulator with a distinctive protected-gauge design and a large red adjustment knob.
This guide examines its published characteristics, explains the relationship between pressure ranges and acetylene safety limits, compares related UWELD regulator configurations, and provides a practical purchasing and quality-control framework.
Explore the UWELD 1C008-0080 Medium Acetylene Regulator for product information and customization inquiries.

Key Takeaways: What Should Industrial Buyers Know?
-
CGA510 cylinder connection: The 1C008-0080 ACE is identified with a CGA510 inlet for compatible acetylene cylinder systems.
-
Single-stage pressure reduction: The regulator uses one pressure-reduction stage and must be selected according to its approved operating characteristics.
-
Dual pressure monitoring: High-contrast gauges provide pressure indications for the supply and delivery sides.
-
Impact-absorbing adjustment design: UWELD advertises a protective knob design intended to improve handling and resistance to certain impacts.
-
Gas-specific identification: The acetylene and oxygen configurations have different pressure ranges, connections, and intended gas services.
-
Pressure safety: The illustrated 0–20 psi outlet range does not mean acetylene may safely be used at 20 psig.
-
B2B procurement: Approved specifications, sample evaluation, batch traceability, and controlled product identification are essential for wholesale orders.
The main selection rule is to verify the complete acetylene system before comparing regulator appearance or unit price.
What Is the UWELD 1C008-0080 Medium Duty Acetylene Regulator?
The UWELD 1C008-0080 ACE is a gas pressure regulator designed to reduce acetylene supply pressure for compatible downstream welding and cutting equipment.
Its single-stage construction uses one regulating stage to control delivery pressure within its approved operating conditions.
The product is intended for professional users who require an appropriate fuel-gas regulator for oxy-acetylene applications.
Published Product Specifications
| Specification | UWELD 1C008-0080 ACE |
|---|---|
| Brand | UWELD |
| Base model | 1C008-0080 |
| Product variant | 1C008-0080 ACE |
| Equipment category | Medium-duty acetylene pressure regulator |
| Regulation type | Single-stage |
| Gas service | Acetylene |
| Cylinder inlet | CGA510 |
| Outlet connection | 9/16"-18 LH |
| Illustrated inlet pressure range | 0–500 psi |
| Illustrated outlet pressure range | 0–20 psi |
| Pressure monitoring | Dual high-contrast gauges |
| Adjustment mechanism | Large red adjustment knob |
| Protective design | Impact-absorbing adjustment feature |
| Applications | Compatible oxy-acetylene welding, cutting, brazing, and heating |
| Business services | Wholesale and OEM inquiries |
Source: UWELD official product listing and the manufacturer's product illustration supplied for this article.
Important: The pressure values above are transcribed from the manufacturer's illustration. The current datasheet must confirm whether they describe gauge ranges, regulator operating ranges, or other rated characteristics. They are not recommended operating settings.
Why Is This Regulator Considered Medium Duty?
The product is marketed for medium-duty industrial applications.
However, the term "medium duty" does not establish a universal flow capacity, continuous operating time, or pressure-control accuracy.
These characteristics require model-specific technical data.
For industrial buyers, the correct question is whether the regulator can satisfy the intended torch or equipment requirements—not whether it carries a medium-duty or heavy-duty label.
How Do Single-Stage Acetylene Regulators Control Pressure?
A single-stage regulator reduces gas pressure through one regulating mechanism.
The regulator responds to changes in gas pressure and delivery demand according to its internal design.
The outlet pressure-control characteristics depend on the regulator's specifications and operating conditions.
Single-Stage vs Two-Stage Pressure Regulation
| Comparison | Single-Stage Regulator | Two-Stage Regulator |
|---|---|---|
| Pressure-reduction stages | One | Two |
| Construction | Generally simpler | Additional regulating stage |
| Delivery-pressure behavior | Depends on design and supply-pressure variation | May provide improved control as inlet pressure changes |
| Application suitability | Suitable for many approved gas applications | Useful for applications requiring particular stability characteristics |
| Maintenance | Model-specific | Model-specific |
| Main purchasing criterion | Approved pressure, flow, and connections | Verified pressure-control performance |
A dual-gauge regulator is not necessarily a two-stage regulator.
The two gauges provide different pressure indications; they do not establish the number of regulating stages.
Why Does Flow Capacity Matter?
A regulator must provide sufficient gas flow for the connected equipment within its approved operating limits.
A small welding tip and an industrial cutting torch may have different fuel-gas consumption requirements.
Regulator suitability depends on the actual flow demand, permitted delivery pressure, supply conditions, and equipment configuration.
Buyers should request relevant pressure-flow performance information for applications with significant gas demand.
How Should Buyers Interpret the 0–500 PSI and 0–20 PSI Ranges?
This is one of the most important technical questions about the UWELD 1C008-0080.
The supplied product illustration identifies:
-
Acetylene inlet pressure range: 0–500 psi.
-
Acetylene outlet pressure range: 0–20 psi.
These values need to be interpreted correctly.
Pressure Range Is Not the Same as Working Pressure
The following measurements describe different things.
| Pressure Specification | Meaning | Purchasing Requirement |
|---|---|---|
| Cylinder supply pressure | Pressure present at the cylinder outlet | Verify the approved cylinder system |
| Regulator inlet rating | Permitted supply-side pressure for the regulator | Obtain the current datasheet |
| Inlet gauge range | Range indicated on the supply-side gauge | Confirm gauge specifications |
| Regulator outlet range | Designed delivery-pressure adjustment range | Verify the model's approved limits |
| Outlet gauge range | Measurement range on the delivery gauge | Do not interpret as a safe operating setting |
| Actual working pressure | Pressure required by the connected equipment | Follow manufacturer instructions and applicable rules |
A regulator may have a gauge that displays values outside the permitted operating range of a particular application.
The measurement scale alone does not authorize use at every indicated pressure.
The Acetylene 15 PSIG Safety Limit
Under U.S. OSHA 29 CFR 1910.253, acetylene must not be generated, piped, or utilized at pressures above 15 psig, subject to the regulation's stated exceptions.
The regulatory limit is approximately 103 kPa gauge pressure.
This means the illustrated 20 psi upper outlet value must not be interpreted as permission to use acetylene at 20 psig.
The actual pressure required by a welding or cutting torch may be considerably lower.
Use must follow the applicable manufacturer's approved operating instructions and workplace regulations.
For the exact regulatory language, see the OSHA oxygen-fuel gas welding and cutting standard.
What Should Distributors Request?
Before approving a bulk order, request the current regulator inlet-pressure rating, outlet adjustment specification, gauge ranges, flow-capacity information, and applicable operating instructions.
This is particularly important when the regulator is being sold to customers who may interpret catalog pressure ranges as recommended operating values.
Why Is CGA510 Cylinder Compatibility Important?
CGA510 is a cylinder connection designation used for certain fuel-gas cylinder arrangements.
It identifies an important interface requirement, but it is not a regulator performance rating.
The UWELD 1C008-0080 ACE is specifically listed with a CGA510 inlet.
For distributors serving customers with compatible cylinders, this provides a clear starting point for technical selection.
CGA510 Inlet vs 9/16"-18 LH Outlet
The two connections perform different functions.
| Connection | Published Specification | Function |
|---|---|---|
| Cylinder inlet | CGA510 | Connects the regulator to a compatible acetylene cylinder valve |
| Regulator outlet | 9/16"-18 LH | Connects to the approved downstream hose or equipment arrangement |
The left-hand outlet thread is an important feature of the acetylene configuration.
However, thread size and handedness alone do not guarantee complete compatibility.
The sealing arrangement, fitting geometry, gas rating, and approved system design must also match.
Common Connection Mistakes
A distributor may experience problems when the regulator has the correct cylinder inlet but an unsuitable outlet fitting.
Other mistakes include ordering the oxygen variant instead of the acetylene version or selecting a product based only on a similar housing shape.
A reliable purchasing system should document both the inlet and outlet connections for each approved SKU.
Is CGA510 Suitable for Every Market?
No.
Cylinder connection standards vary among markets and gas supply arrangements.
Importers should confirm the actual cylinder valve specifications used by their customers.
If several connection configurations are required, they should be treated as separate approved product variants rather than interchangeable stock.
What Are the Benefits of the High-Contrast Gauges and Red Adjustment Knob?
UWELD highlights the visibility and adjustment features of the 1C008-0080 regulator.
These features are relevant to product usability, but their actual performance should be evaluated separately.
High-Contrast Pressure Gauges
The regulator features two pressure gauges within a protective housing arrangement.
The high-contrast dial design is intended to improve readability.
For professional buyers, relevant evaluation criteria include:
-
Scale legibility.
-
Gauge measurement range.
-
Measurement accuracy.
-
Mechanical protection.
-
Clear gas-service identification.
-
Inspection and calibration requirements.
A gauge that is easy to read still requires appropriate accuracy and approved operating limits.
Large Red Adjustment Knob
The acetylene variant uses a distinctive red adjustment knob.
UWELD describes this knob as having an impact-absorbing design.
Its larger form may be relevant to operator handling and adjustment accessibility.
However, the manufacturer's description does not establish a specific impact-test result or guaranteed resistance to accidental drops.
Buyers seeking quantified durability requirements should request supporting test documentation.
Protected Gauge and Adjustment Arrangement
The black housing surrounds portions of the gauge and adjustment assembly.
This design distinguishes the product visually from conventional exposed dual-gauge regulators.
For equipment importers, it may also provide a recognizable product identity within a professional gas-control equipment range.
Nevertheless, the housing should not be treated as a substitute for correct transport, handling, installation, or maintenance procedures.
Acetylene vs Oxygen: What Is Different in the 1C008-0080 Series?
UWELD lists separate acetylene and oxygen configurations within the 1C008-0080 product family.
Although their overall designs appear related, they are not interchangeable.
UWELD 1C008-0080 ACE vs OXY
| Specification | 1C008-0080 ACE | 1C008-0080 OXY |
|---|---|---|
| Gas service | Acetylene | Oxygen |
| Adjustment knob | Red | Green |
| Cylinder inlet | CGA510 | CGA540 |
| Outlet connection | 9/16"-18 LH | 9/16"-18 RH |
| Illustrated inlet pressure range | 0–500 psi | 0–4000 psi |
| Illustrated outlet pressure range | 0–20 psi | 0–225 psi |
| Pressure regulation | Single-stage | Single-stage |
| Intended application | Approved fuel-gas control | Approved oxygen pressure control |
The pressure ranges and connections above are taken from the UWELD product illustration. Verify the current specifications and ratings before purchasing or operating either version.
Why the Color Difference Matters
Color provides a useful visual identification cue.
However, color should never replace model identification or technical verification.
Buyers should confirm the exact gas service through the product label, approved specifications, and complete SKU.
Can the Acetylene Regulator Be Used for Oxygen?
No substitution should be made unless the exact product configuration is explicitly approved for the intended gas.
Acetylene and oxygen regulators have different service requirements and potentially different internal components, pressure ratings, and connections.
For oxygen service, review the separate UWELD 1C008-0080 Oxygen Regulator.
Procurement recommendation: Use separate inventory codes for the ACE and OXY versions and include the full gas-service designation on purchase orders.
Which Industrial Applications Require a CGA 510 Acetylene Regulator?
The UWELD 1C008-0080 ACE may be considered for compatible oxy-acetylene systems used in welding, cutting, heating, and brazing.
The final application must be supported by the regulator's approved specifications and the requirements of the connected equipment.
Application Selection Matrix
| Application | Regulator Function | Key Buyer Requirement |
|---|---|---|
| Oxy-acetylene welding | Controls the acetylene supply | Torch and welding-tip compatibility |
| Steel cutting | Supplies fuel gas to compatible cutting equipment | Fuel flow, pressure and nozzle requirements |
| Industrial fabrication | Supports approved oxy-fuel processes | Suitable equipment ratings |
| Equipment maintenance | Provides acetylene pressure regulation | Serviceability and connection compatibility |
| Brazing and heating | Supplies fuel for compatible heating equipment | Torch and burner specifications |
| Equipment distribution | Supplies a replaceable regulator SKU | Clear markings and stable configuration |
Metal Fabrication
Fabrication workshops may use oxy-acetylene systems for suitable welding, cutting, or heating tasks.
The acetylene regulator controls the fuel-gas supply, while a separate oxygen regulator manages oxygen delivery.
Both regulators must be compatible with their respective gases and connected equipment.
Industrial Repair
Maintenance contractors may use oxy-acetylene equipment for approved repair and heating applications.
In these environments, regulator handling, connection suitability, replacement availability, and clear product identification are important purchasing considerations.
Welding Equipment Distribution
For distributors, the 1C008-0080 ACE offers a specific regulator configuration that can be identified by its model number, red adjustment knob, CGA510 inlet, and left-hand outlet.
This makes complete SKU documentation especially valuable when supplying replacement equipment.
How Does the 1C008-0080 Compare With Other UWELD Acetylene Regulators?
UWELD supplies several acetylene regulator configurations with different product positioning and component arrangements.
Model Comparison
| UWELD Model | Published Characteristics | Main Purchasing Consideration |
|---|---|---|
| 1C008-0080 ACE | Single-stage, CGA510, protected gauges, red adjustment knob | Connection-specific industrial purchasing |
| 1C008-0044 ACE | TA90 single-stage design, forged brass, relief and shut-off features | TA90 configuration and connection requirements |
| 1C008-0005 | Medium-duty forged brass regulator with dual gauges | Conventional medium-duty product selection |
| 1C008-0008 | G350 industrial acetylene regulator | Alternative industrial pressure-control configuration |
The table identifies available product characteristics rather than verified differences in pressure accuracy, durability, or operating cost.
When Is the 1C008-0080 a Good Candidate?
This model is particularly relevant when a buyer needs a published CGA510 acetylene configuration and values its protected-gauge and adjustment design.
The exact suitability must still be confirmed using the current technical datasheet.
When Should Buyers Consider the TA90?
The UWELD TA90 Acetylene Regulator 1C008-0044 offers a different single-stage arrangement with documented relief and shut-off features.
Buyers should compare the actual pressure requirements, inlet and outlet fittings, protection features, and quality documents before selecting either product.
A different appearance does not automatically mean better technical performance.
How Can Distributors Verify Regulator Quality Before Wholesale Orders?
A professional purchasing review should cover component identity, manufacturing consistency, gas compatibility, and required functional verification.
Product photographs cannot establish these characteristics.
Quality-Control Checklist
| Inspection Area | Verification Requirement |
|---|---|
| Model identification | Correct 1C008-0080 ACE SKU |
| Gas-service marking | Clearly identified acetylene configuration |
| Cylinder inlet | Correct CGA510 connection |
| Outlet fitting | Approved 9/16"-18 LH configuration |
| Pressure gauges | Specified ranges, markings and inspection |
| Adjustment mechanism | Correct operation and condition |
| Regulator housing | Approved assembly and physical condition |
| Internal components | Conformance to approved specifications |
| Gas tightness | Qualified leakage verification |
| Pressure-control performance | Approved functional test |
| Product documentation | Datasheet and applicable records |
| Packaging | Correct model labeling and protection |
| Traceability | Batch or order identification |
Why Gas-Tightness Verification Matters
Acetylene is a flammable gas.
A regulator must be evaluated for appropriate gas integrity using the approved inspection and testing procedures.
A visual inspection alone cannot establish that the assembly is leak-free.
Gas testing should only be performed by qualified personnel using suitable equipment and procedures.
What Standard Should Buyers Reference?
ISO 2503:2009, including its applicable amendment, specifies requirements for pressure regulators used with certain gases in welding, cutting, and allied processes. Its scope includes dissolved acetylene.
This is a relevant technical reference when establishing product requirements.
However, the existence of a standard does not mean that every regulator has been independently certified to it.
A supplier should provide applicable conformity or testing evidence for the exact purchased configuration.
How Should Buyers Manage Repeat Orders?
An approved sample should be linked to a controlled product specification.
The specification should identify the gas service, inlet and outlet connections, pressure ratings, gauge configuration, component requirements, and packaging.
Any proposed change affecting performance, compatibility, or safety should be reviewed before approval.
This helps distributors avoid receiving visually similar products with different functional specifications.
What Affects Wholesale Acetylene Regulator Pricing?
The cost of an industrial regulator depends on its configuration and purchasing requirements.
For the 1C008-0080, commercial factors may include the gauge and housing arrangement, connection specifications, adjustment mechanism, inspection requirements, packaging, and order volume.
Total Purchasing Cost
For industrial importers, total cost includes more than the supplier's unit price.
Total Sourcing Cost = Product Cost + Inspection + Packaging + Freight + Inventory + Expected After-Sales Cost
| Cost Factor | Procurement Consideration |
|---|---|
| Product construction | Materials and component configuration |
| Gauge arrangement | Gauge and housing requirements |
| Cylinder fitting | CGA510 and required connection specifications |
| Product testing | Inspection and documentation scope |
| OEM customization | Branding and packaging requirements |
| Quantity | Sample and bulk order conditions |
| Shipping | Destination and transport arrangements |
| After-sales support | Replacement and service responsibilities |
A lower initial quotation is not automatically the most economical choice.
For distributors, incompatible products or inconsistent repeat orders may create additional support and replacement costs.
How Should Buyers Compare Two Quotations?
Use equivalent technical specifications and order quantities.
Confirm that both quotations include the required regulator configuration, packaging, documentation, inspection, and delivery terms.
Without comparable quotations or measured failure data, no specific cost-saving percentage should be claimed.
How to Qualify a CGA 510 Acetylene Regulator in Three Steps
A structured purchasing process can help importers and distributors avoid technical mistakes.
Step 1: Verify Cylinder and Gas Compatibility
Identify the intended acetylene cylinder, the required inlet connection, and the downstream equipment.
Confirm whether CGA510 is the correct approved cylinder interface.
Decision: Exclude products with incompatible gas service or cylinder connections.
Step 2: Confirm Pressure and Functional Specifications
Review the current datasheet, approved pressure ranges, gas flow requirements, outlet connection, gauge specifications, and applicable safety documentation.
Do not treat the illustrated 20 psi outlet range as a recommended working pressure.
Decision: Approve only configurations meeting the intended application requirements.
Step 3: Evaluate Samples and Commercial Supply
Review representative samples, inspection records, packaging, product identification, MOQ, lead time, and after-sales arrangements.
Decision: Select a configuration that meets both technical and purchasing requirements.
Buyers can request technical specifications from UWELD before committing to bulk orders.
Practical Procurement Scenario: Preventing ACE and OXY SKU Mix-Ups
Consider an industrial equipment importer supplying gas regulators to professional welding distributors.
The importer plans to source both acetylene and oxygen regulators from the 1C008-0080 product family.
The two products have related housing designs, but their connections and gas-service requirements differ.
This is an illustrative procurement scenario, not a documented UWELD customer case study.
The Purchasing Risk
If the importer records only the base model number, the warehouse may struggle to distinguish between the acetylene and oxygen versions.
That can create ordering and product-identification errors.
Recommended Control Method
First: Assign separate inventory references to 1C008-0080 ACE and 1C008-0080 OXY.
Second: Record the complete inlet and outlet specifications for each model.
Third: Use different product labels and approved packing lists.
Fourth: Confirm the relevant gas-service markings during incoming inspection.
Fifth: Require approval before substitutions or technical revisions.
Expected Benefits
This approach can help reduce SKU confusion and make product identification, repeat purchasing, and after-sales support more consistent.
Any actual reduction in returns or customer complaints would need to be measured from operational records.
OEM/ODM Acetylene Regulator Supply for International Brands
UWELD supports OEM and wholesale inquiries for its gas-control equipment.
International distributors may require private-label packaging, product identification, documentation, and approved market-specific configurations.
Possible customization requests include:
-
Private-label branding.
-
Product and carton labels.
-
Approved packaging artwork.
-
Model identification.
-
Relevant language documentation.
-
Technically feasible connection configurations.
Changes affecting the gas path, regulating mechanism, rated pressure, or safety-related components require appropriate engineering review.
Recommended OEM Process
| Stage | Main Requirement |
|---|---|
| Requirements review | Define gas service, application, market |
| Technical selection | Confirm approved regulator configuration |
| Engineering evaluation | Review proposed technical changes |
| Sample approval | Verify product identity and performance |
| Branding approval | Confirm labels and packaging |
| Production inspection | Establish acceptance requirements |
| Shipment | Verify quantities and documentation |
| Repeat orders | Maintain approved technical revisions |
UWELD's Solutions page describes its customization and manufacturing cooperation capabilities.
MOQ, Samples and Lead Time
According to UWELD's FAQs, MOQ varies according to the product and customization requirements.
Samples may be arranged under agreed conditions.
Delivery times should be confirmed according to product availability, order quantity, and customization scope.
These are commercial matters that should be established during quotation rather than assumed from general product descriptions.
What Should Buyers Include in a 1C008-0080 Acetylene Regulator RFQ?
A complete request for quotation helps ensure that the supplier identifies the exact required configuration.
| RFQ Field | Required Information |
|---|---|
| Product | Medium-duty acetylene regulator |
| Model | 1C008-0080 ACE |
| Gas service | Acetylene |
| Cylinder connection | CGA510 |
| Regulator outlet | 9/16"-18 LH |
| Pressure requirements | Confirm approved inlet/outlet ratings |
| Flow demand | Connected equipment requirements |
| Application | Welding, cutting, brazing, heating |
| Gauge configuration | Required scales and identification |
| Product documentation | Current technical datasheet and inspection records |
| OEM requirements | Logo, labels, packaging |
| Sample quantity | Required evaluation units |
| Bulk quantity | Expected initial and repeat orders |
| Destination | Country or region |
| Delivery | Required schedule and shipping terms |
Providing the full model and connection specifications can help avoid unnecessary quotation revisions.
Looking for a CGA 510 acetylene regulator for wholesale distribution? Contact UWELD to request the 1C008-0080 ACE datasheet, sample information, connection confirmation, OEM options, and bulk pricing.
Frequently Asked Questions About CGA 510 Acetylene Regulators
1. What is a CGA 510 acetylene regulator?
A CGA 510 acetylene regulator is a pressure regulator configured with a CGA510 inlet for a compatible acetylene cylinder valve. The complete regulator must also meet the required gas, pressure, flow, and outlet-connection specifications.
2. What is the UWELD 1C008-0080 ACE used for?
The UWELD 1C008-0080 ACE is intended for compatible acetylene pressure-control applications, including approved oxy-acetylene welding, cutting, brazing, and heating systems.
3. Is the UWELD 1C008-0080 single-stage or two-stage?
It is identified as a single-stage regulator. Having two pressure gauges does not mean it contains two pressure-reduction stages.
4. What are the published pressure ranges?
The supplied UWELD illustration lists an inlet range of 0–500 psi and an outlet range of 0–20 psi. Buyers should verify the current datasheet to determine the exact regulator ratings and gauge specifications.
5. Can acetylene be used at 20 psi because the outlet range reaches 20 psi?
No. Under U.S. OSHA 29 CFR 1910.253, acetylene utilization is limited to 15 psig, subject to the regulation's stated exceptions. The actual working pressure must comply with the manufacturer's instructions and applicable safety requirements.
6. What outlet connection does the regulator use?
The manufacturer's illustration identifies a 9/16"-18 LH outlet. Buyers must also verify the fitting geometry, gas rating, and compatibility with the downstream hose or protective equipment.
7. Can the acetylene regulator be used for oxygen?
The ACE configuration must not be substituted for oxygen service. UWELD lists a separate 1C008-0080 OXY model with different connections and pressure characteristics.
8. What does the impact-absorbing adjustment knob provide?
UWELD advertises a knob design intended to improve handling and provide impact-absorbing characteristics. Buyers requiring a specific durability rating should request supporting technical or test information.
9. What should distributors check before placing a bulk order?
They should verify the complete model, gas service, inlet and outlet fittings, pressure and flow requirements, gauge configuration, applicable standards, inspection records, packaging, MOQ, and delivery conditions.
10. Does UWELD support OEM acetylene regulator orders?
UWELD supports OEM/ODM inquiries involving branding, packaging, and technically feasible customization. The exact options, minimum quantity, sample requirements, and production schedule must be agreed for each project.
Conclusion
Selecting the correct CGA 510 acetylene regulator requires careful evaluation of the complete gas system rather than the regulator's appearance or price alone.
The UWELD 1C008-0080 ACE combines single-stage pressure regulation, high-contrast dual gauges, a protected housing arrangement, and an impact-absorbing adjustment knob in a medium-duty product configuration.
For industrial buyers, the critical purchasing requirements include correct CGA510 cylinder compatibility, verified 9/16"-18 LH outlet connections, approved pressure limits, appropriate flow capacity, and documented product quality.
The regulator's published 0–20 psi outlet range must not be confused with the safe working pressure for acetylene equipment.
For welding equipment importers, distributors, and OEM brands, reliable procurement also depends on accurate SKU identification, sample approval, consistent batch specifications, and clear after-sales responsibilities.
UWELD supplies acetylene regulators and related industrial welding and cutting equipment for international markets.
To evaluate this product, visit the UWELD 1C008-0080 ACE product page, explore UWELD Gas Cutting Equipment, or contact UWELD to request current technical specifications, sample availability, OEM customization options, and a wholesale quotation.